Цифровое реле задержки времени переменного тока 110 В 220 В T3230 24 В, светодиодный дисплей, таймер цикла
Товар
- 0 раз купили
- 0 оценка
- 50 осталось
- 0 отзывов
Доставка
Характеристики
Описание
【 Regular version 】:
Description:
Time range :0-999 hours 0-999 minutes 0-999 seconds Three kinds can be selected as required
Display panel size :79mm*43mm
Installation size :71mm*40mm*24mm
Feature set: A combination of 18 features
Relay :20A relay, power <1800W
Working voltage :DC12V/DC24V/AC110-220V [Optional]
Product instructions:
Before use, first remind the user to pay attention to one point, after setting the data must wait for 6s, 6s module will automatically save the memory set data.
Press the SET key once to enter the time setting mode, the red nixie will blink, adjust the timing time T1 by pressing the key to add or subtract the key, press the SET key again after T1 is SET, the green nixie will blink, press the timing time TT2 by pressing the key to add or subtract the time, press the set key again after TT2 is set. The system will automatically save the memory setting time or wait for 6s. After 6s, the module will automatically save the data.
Press and hold SET to enter parameter setting mode. There are two sets of parameters for users to choose PO and P1. In the current mode, tap SET to toggle PO P1. Under the PO parameter, you can add or subtract the key to set your own timing mode. Under P1 parameter, you can add or subtract by pressing the button
Set the working mode.
P0--1:T1 The timing mode is minute
P0--2:T1 Indicates the timing mode
P1-0: Delay T1 time after relay pull (T1 timing)
P1-1 Delay T1 time relay release (T1 timing)
P1-2: After the delay T1 time, the relay is drawn (T1 timing), and then after the delay T2 time
Relay release (T2 timing), end.
P1--3: After the delay T1 time, the relay is released (T1 timing) and then after the delay T2 time
Relay pull (T2 timing), end.
P1--4: After the delay T1 time, the relay is drawn (T1 timing), and then after the delay T2 time
Relay release (T2 timing), repeat cycle.
P1-5: After the delay T1 time, the relay is released (T1 timing) and then after the delay T2 time
Relay pull (T2 timing), repeat cycle.
Example: For example, a customer needs to start for 10 seconds and shut down for 20 seconds
Ring. The setting method is as follows:
T1 is set to 10, T2 is set to 20
P0-0(T1 timing range is seconds)
P1-5(Timer working mode is to work first and then stop the cycle)
Restore factory Settings: Due to the wrong setting caused by data confusion, can not SET when you can choose to restore factory Settings, press and hold set and then power on.